Propuesta para una iluminación eficiente en el edificio de Ciencias Forenses y Medicina Legal de San Joaquín de Flores, Heredia
bk-old-una.tipo | Licenciatura en Gestión Ambiental | es_ES |
dc.contributor.author | Reyes Pérez, Paola | |
dc.date.accessioned | 2017-04-27T15:19:30Z | |
dc.date.available | 2017-04-27T15:19:30Z | |
dc.date.created | 2017-04-27 | |
dc.date.issued | 2016 | |
dc.description.abstract | Se realizó un estudio de iluminación en las luminarias del edificio de Ciencias Forense y Medicina Legal del OIJ, donde se determinó la capacidad luminosa bajo la norma INTE 31- 08-06 2014, donde se diagnosticó el nivel de iluminación en el edificio según la actividad de labor que se realiza. En el inventario de lámparas, se encontró la mayor parte fluorescentes tubulares de tipo T12 y T8 de la marca Sylvania y Philips. La etapa de medición se inició en diciembre del 2013 y concluyó en julio del 2014, en este lapso se realizó el inventario de lámparas del edificio para poder determinar el consumo energético en iluminación en el edificio, la calidad energética de las luminarias de algunas habitaciones, así como los niveles de iluminación de los espacios estudiados en la edificación. Todas estas mediciones se tomaron en cuenta las distintas áreas de la infraestructura, a excepción de las bodegas de indicios y archivos de casos especiales debido al reglamento de la institución. Los resultados más relevantes durante el estudio fueron, los departamentos de Clínica Médico Forense de Medicina Forense y Bioquímica de Ciencias Forense del OIJ. Estos departamentos tienen un consumo energético correspondiente en iluminación, de un valor aproximado 30,000.00 kWh/año en la Clínica y valor 25,000.00 kWh/año en Bioquímica de un consumo anual aproximado 80,000.00 kWh/año. Esto presentan un 37.5% del consumo anual para la Clínica y un 31.3% de consumo anual para Bioquímica, significando que requieren el uso de las iluminación artificial durante sus tareas. De igual manera, estos dos departamentos emiten CO2 equivalente por año con un valor aproximado a un 39% en Clínica Médico Forense y de un 32% en Bioquímica, debido al uso constante de la iluminación representan el mayor porcentaje en el edificio. El mismo caso, con el ocurre con la emisiones potenciales de mercurio, donde los dos departamentos tienen un valor aproximado de 5000 mg de Hg. | es_ES |
dc.description.abstract | A lighting study was carried out in the luminaires of the Forensic Sciences building and Legal Medicine of the OIJ, where the luminous capacity was determined under the INTE 31- 08-06 2014, where the lighting level in the building was diagnosed according to activity of work being done. In the inventory of lamps, most of the Tubular fluorescent type T12 and T8 from Sylvania and Philips. The measurement stage began in December 2013 and concluded in July 2014, in this The building's lamp inventory was carried out in order to determine consumption energy in lighting in the building, the energy quality of the luminaires of some rooms, as well as the lighting levels of the spaces studied in the edification. All these measurements were taken into account the different areas of the infrastructure, an exception of the evidence warehouses and special case files due to the regulations of the institution. The most relevant results during the study were, the departments of Clinic Forensic Doctor of Forensic Medicine and Biochemistry of Forensic Sciences of the OIJ. These the departments have a corresponding energy consumption in lighting, of a value approximate 30,000.00 kWh / year in the Clinic and value 25,000.00 kWh / year in Biochemistry of an approximate annual consumption of 80,000.00 kWh / year. This represents 37.5% of consumption annual for the Clinic and a 31.3% annual consumption for Biochemistry, meaning that requires the use of artificial lighting during their tasks. Similarly, these two departments emit CO2 equivalent per year with a value Approximately 39% in the Forensic Medical Clinic and 32% in Biochemistry, due to the Constant use of lighting represents the largest percentage in the building. the same This is the case with potential mercury emissions, where the two departments they have an approximate value of 5000 mg of Hg. | |
dc.identifier.citation | Reyes-Pérez, P. (2016). Propuesta para una iluminación eficiente en el edificio de Ciencias Forenses y Medicina Legal de San Joaquín de Flores, Heredia. (Tesis de Licenciatura en Gestión Ambiental). Universidad Nacional | es_ES |
dc.identifier.uri | http://hdl.handle.net/11056/13663 | |
dc.language.iso | es | es_ES |
dc.publisher | Universidad Nacional (Costa Rica). Escuela de Ciencias Agrarias | es_ES |
dc.rights | Acceso abierto | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | MANEJO AMBIENTAL | es_ES |
dc.subject | ILUMINACIÓN | es_ES |
dc.subject | POLÍTICA AMBIENTAL | es_ES |
dc.subject | POLÍTICA ENERGÉTICA | es_ES |
dc.subject | ELECTRICIDAD | es_ES |
dc.subject | LUZ | es_ES |
dc.subject | EFICIENCIA | es_ES |
dc.title | Propuesta para una iluminación eficiente en el edificio de Ciencias Forenses y Medicina Legal de San Joaquín de Flores, Heredia | es_ES |