Logotipo del repositorio
 

Characterisation of IndoorAir Quality in Large Urban Centres in Central America

dc.contributor.authorAlfaro, María Del Rosario
dc.date.accessioned2026-07-02T18:58:20Z
dc.date.available2026-07-02T18:58:20Z
dc.date.issued1997
dc.description.abstractLevels of gas and particle-phase substances present in the indoor air at non-industrial sites in Costa Rica, El Salvador, Guatemala, Honduras, Nicaragua, and Panama; including offices, hospitals and restaurants, were measured during 1993 and 1994. Samples collected at 40 sites were analysed for respirable suspended particles (RSP, d50 <3.5 μm), ultraviolet RSP (UV-RSP) as a marker for environmental tobacco smoke, carbon monoxide, carbon dioxide, and nicotine. Levels of RSP were very high at several sites, varying within the ranges of 34-421 μg/m3 in restaurants, 21-242 μg/m3 in hospitals and 13-196 μg/m3 in offices. Carbon monoxide levels were also high at several sites with peak concentrations reaching 29, 20, and 19 ppm, respectively, in an office, a hospital and a restaurant. Infiltration and penetration of outdoor pollutants into the indoor environment occurred at all sites studied.
dc.description.abstractDurante 1993 y 1994 se midieron los niveles de sustancias gaseosas y particuladas presentes en el aire interior de lugares no industriales en Costa Rica, El Salvador, Guatemala, Honduras, Nicaragua y Panamá, incluyendo oficinas, hospitales y restaurantes. Se analizaron muestras recolectadas en 40 lugares para determinar la presencia de partículas respirables en suspensión (RSP, d50 <3,5 μm), RSP ultravioleta (UV-RSP) como marcador del humo de tabaco ambiental, monóxido de carbono, dióxido de carbono y nicotina. Los niveles de RSP fueron muy altos en varios lugares, variando entre 34 y 421 μg/m³ en restaurantes, entre 21 y 242 μg/m³ en hospitales y entre 13 y 196 μg/m³ en oficinas. Los niveles de monóxido de carbono también fueron altos en varios lugares, con concentraciones máximas que alcanzaron 29, 20 y 19 ppm, respectivamente, en una oficina, un hospital y un restaurante. En todos los lugares estudiados se produjo infiltración y penetración de contaminantes exteriores en el ambiente interior.
dc.description.procedenceEscuela de Ciencias Ambientaleses_ES
dc.description.sponsorshipUniversidad Nacional, Costa Ricaes_ES
dc.identifier.doi10.1177/1420326X9700600604
dc.identifier.issn1420326X
dc.identifier.urihttps://hdl.handle.net/11056/35083
dc.publisherUniversidad Nacional, Costa Ricaes_ES
dc.rightsAcceso abierto
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceRevista Indoor and Built Environment Volumen 6 (1997) número 6 páginas 337-343
dc.subjectEL SALVADOR
dc.subjectGUATEMALA
dc.subjectHONDURAS
dc.subjectNICARAGUA
dc.subjectCOSTA RICA
dc.subjectPANAMA
dc.subjectHASPITALS
dc.subjectHOSPITALES
dc.subjectRESTAURANTS
dc.subjectRESTAURANTES
dc.titleCharacterisation of IndoorAir Quality in Large Urban Centres in Central America
dc.typehttp://purl.org/coar/resource_type/c_6501es_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
Characterisation indoor air.pdf
Tamaño:
635.9 KB
Formato:
Adobe Portable Document Format
Descripción:
Articulo Científico

Bloque de licencias

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
919 B
Formato:
Item-specific license agreed upon to submission
Descripción: