Characterisation of IndoorAir Quality in Large Urban Centres in Central America
| dc.contributor.author | Alfaro, María Del Rosario | |
| dc.date.accessioned | 2026-07-02T18:58:20Z | |
| dc.date.available | 2026-07-02T18:58:20Z | |
| dc.date.issued | 1997 | |
| dc.description.abstract | Levels of gas and particle-phase substances present in the indoor air at non-industrial sites in Costa Rica, El Salvador, Guatemala, Honduras, Nicaragua, and Panama; including offices, hospitals and restaurants, were measured during 1993 and 1994. Samples collected at 40 sites were analysed for respirable suspended particles (RSP, d50 <3.5 μm), ultraviolet RSP (UV-RSP) as a marker for environmental tobacco smoke, carbon monoxide, carbon dioxide, and nicotine. Levels of RSP were very high at several sites, varying within the ranges of 34-421 μg/m3 in restaurants, 21-242 μg/m3 in hospitals and 13-196 μg/m3 in offices. Carbon monoxide levels were also high at several sites with peak concentrations reaching 29, 20, and 19 ppm, respectively, in an office, a hospital and a restaurant. Infiltration and penetration of outdoor pollutants into the indoor environment occurred at all sites studied. | |
| dc.description.abstract | Durante 1993 y 1994 se midieron los niveles de sustancias gaseosas y particuladas presentes en el aire interior de lugares no industriales en Costa Rica, El Salvador, Guatemala, Honduras, Nicaragua y Panamá, incluyendo oficinas, hospitales y restaurantes. Se analizaron muestras recolectadas en 40 lugares para determinar la presencia de partículas respirables en suspensión (RSP, d50 <3,5 μm), RSP ultravioleta (UV-RSP) como marcador del humo de tabaco ambiental, monóxido de carbono, dióxido de carbono y nicotina. Los niveles de RSP fueron muy altos en varios lugares, variando entre 34 y 421 μg/m³ en restaurantes, entre 21 y 242 μg/m³ en hospitales y entre 13 y 196 μg/m³ en oficinas. Los niveles de monóxido de carbono también fueron altos en varios lugares, con concentraciones máximas que alcanzaron 29, 20 y 19 ppm, respectivamente, en una oficina, un hospital y un restaurante. En todos los lugares estudiados se produjo infiltración y penetración de contaminantes exteriores en el ambiente interior. | |
| dc.description.procedence | Escuela de Ciencias Ambientales | es_ES |
| dc.description.sponsorship | Universidad Nacional, Costa Rica | es_ES |
| dc.identifier.doi | 10.1177/1420326X9700600604 | |
| dc.identifier.issn | 1420326X | |
| dc.identifier.uri | https://hdl.handle.net/11056/35083 | |
| dc.publisher | Universidad Nacional, Costa Rica | es_ES |
| dc.rights | Acceso abierto | |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | en |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.source | Revista Indoor and Built Environment Volumen 6 (1997) número 6 páginas 337-343 | |
| dc.subject | EL SALVADOR | |
| dc.subject | GUATEMALA | |
| dc.subject | HONDURAS | |
| dc.subject | NICARAGUA | |
| dc.subject | COSTA RICA | |
| dc.subject | PANAMA | |
| dc.subject | HASPITALS | |
| dc.subject | HOSPITALES | |
| dc.subject | RESTAURANTS | |
| dc.subject | RESTAURANTES | |
| dc.title | Characterisation of IndoorAir Quality in Large Urban Centres in Central America | |
| dc.type | http://purl.org/coar/resource_type/c_6501 | es_ES |
Archivos
Bloque original
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- Characterisation indoor air.pdf
- Tamaño:
- 635.9 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Articulo Científico
Bloque de licencias
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 919 B
- Formato:
- Item-specific license agreed upon to submission
- Descripción: