Show simple item record

dc.contributor.authorCalderón-Mata, Angélica
dc.contributor.authorArce Corrales, Luis Pablo
dc.contributor.authorMejías, Ricardo
dc.date.accessioned2022-12-07T22:54:52Z
dc.date.available2022-12-07T22:54:52Z
dc.date.issued2018-07-26
dc.identifier.issn2215-3470
dc.identifier.urihttp://hdl.handle.net/11056/24454
dc.description.abstractIn Costa Rica there is not an explicit recommendation given by the Regulatory Authorities for the utilization of a specific Phantom; that is why experts have to explore what is offered in the market. One of the most remarkable equipment is Normi Mam Digital made by PTW. This article introduces the results of image and dosimetry quality control, applied to the Normi Mam Digital Phantom to validate how the equipment complies with the recommendations of Human Health Series no. 17. The obtained results were satisfactory and achieved the regulatory tolerances by international sanitary organizations.es_ES
dc.description.abstractEn Costa Rica no hay una recomendación explícita de las autoridades competentes para la utilización de un fantoma concreto, de ahí que los expertos deben explorar lo que ofertan los proveedores, entre los que destaca el fantoma Normi Mam Digital del fabricante PTW. Este artículo presenta los resultados del control de calidad dosimétrico y de imagen, aplicados al fantoma Normi Mam Digital para validarlo como equipo que cumple las recomendaciones del Human Health Series no. 17. Los resultados obtenidos fueron satis-factorios, logrando comprobar que los equipos cumplen con las tolerancias recomendadas por órganos sanitarios internacionales.es_ES
dc.description.abstractNa Costa Rica não há uma recomendação explícita das autoridades competentes para utilizar um fantoma concreto, razão pela qual os expertos devem explorar o que os fornecedores oferecem; sendo um dos des-taques o fantoma Normi Mam Digital do fabricante PTW. Este artigo apresenta os resultados do controle de qualidade dosimétrico e de imagem aplicados no fantoma Normi Mam Digital para legitimá-lo como equipamento que cumpre as recomendações do Human Health Series no. 17. Os resultados obtidos foram satisfatórios, comprovando que os equipamentos cumprem com as tolerâncias recomendadas pelos órgãos sanitários internacionais.es_ES
dc.language.isoespes_ES
dc.publisherUniversidad Nacional, Costa Ricaes_ES
dc.rightsAcceso abiertoes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.sourceUniciencia. Vol. 32 No 2 (2018). Julio-Diciembrees_ES
dc.subjectX-RAYSes_ES
dc.subjectTECHNOLOGYes_ES
dc.subjectMEDICINEes_ES
dc.subjectRADIACIONes_ES
dc.subjectENERGIA RADIANTEes_ES
dc.subjectRAIOS Xes_ES
dc.titleControl de calidad de imagen y dosimetría, para mamografía digital, utilizando el fantoma Normi Mam Digitales_ES
dc.title.alternativeImage and dosimetry quality control for digital mammography by using the Normi Mam Digital phantom
dc.title.alternativeControle de qualidade de imagem e dosimetria, para mamografia digital, utilizando o fantoma Normi Mam Digital
dc.typehttp://purl.org/coar/resource_type/c_6501es_ES
dc.description.procedenceDepartamento de Físicaes_ES
dc.identifier.doihttps://doi.org/10.15359/ru.32-2.5


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Acceso abierto
Except where otherwise noted, this item's license is described as Acceso abierto