Mora Aparicio, CarmenAlfaro-Chinchilla, CarolinaPerez-Molina, Junior PastorVega-Guzmán, Ilena2022-11-082022-11-082022-01-312215-3470http://hdl.handle.net/11056/24261The objective of the study was to analyze the environmental contribution, in terms of removal of physicochemical and microbiological pollutants, from the Los Tajos Wastewater Treatment Plant (WWTP) to the Torres River. Physicochemical and microbiological data was analyzed including WWTP inflows and outflows (OBD, OCD, TSS, STT, N-NH4 +, P-PO4 3-, Oils, MBAS, and fecal coliforms). The difference in the concentration of pollutants in the Torres River before and after the construction of the WWTP was analyzed using R 3.6.1, associated with seasonality. According to the Dutch Index Methodology, the Torres River was severely polluted before the construction of the WWTP, and the degree of contamination increases following the WWTP discharge, mainly during the rainy season. The WWTP shows significant removal of seven of the eight parameters analyzed, with the most representative removal percentages being: TSS (68.5%), OBD (49.8%), and Oils (54.7%). The quantitative contribution of the WWTP to the Torres River was demonstrated by removing thousands of Mg of pollutants from wastewater during the years of operation (2015-2020), mainly OCD (26,791.8 Mg), STT (24,162.6 Mg), OBD (12,290.0 Mg), and TSS (30,267.7 Mg). Finally, building the WWTP’s next stages, including secondary treatment, is needed to improve the removal of organic matter, surfactants, and nutrients.El objetivo del estudio fue analizar el aporte ambiental hacia la calidad del río Torres considerando la remoción de contaminantes fisicoquímicos y microbiológicos de la planta de tratamiento de aguas residuales (PTAR) Los Tajos.Se realizó el análisis de datos fisicoquímicos y microbiológicos de las aguas de afluente y efluente de la PTAR (DBO, DQO, SST, STT, N-NH4+, P-PO43-, GyA, SAAM y coliformes fecales principalmente) y se analizó la variación en concentración de contaminantes en el río Torres previo y posterior a la construcción de la PTAR, que realiza un tratamiento primario a las aguas, todo asociado a la estacionalidad. Los datos se analizaron en R versión 3.6.1. Según la metodología del índice holandés, el río Torres se clasificó severamente contaminado previo a la construcción de la PTAR, y actualmente aumenta su grado de contaminación después de la descarga de la PTAR, principalmente en época lluviosa. La PTAR presenta remoción significativa para siete de los ocho parámetros analizados, los porcentajes de remoción más representativos son: SST (68.5 %), DBO (49.8 %) y GyA (54.7 %). Se demostró el aporte cuantitativo de la PTAR al río Torres removiendo toneladas de contaminantes de las aguas residuales desde el 2015 hasta el 2020, principalmente DQO (26,791.8 Mg), SST (24,162.6 Mg), DBO (12,290.0 Mg) y STT (30,267.7 Mg). Finalmente se dejó en evidencia la necesidad de construir las siguientes etapas de la PTAR que incluyen tratamiento secundario, que mejoraría la remoción de materia orgánica, surfactantes y nutrientes.O estudo teve como objetivo analisar a contribuição ambiental na qualidade do rio Torres considerando a remoção de contaminantes físico-químicos e microbiológicos da Estação de Tratamento de Águas Residuais (ETAR) Los Tajos.Foi realizada a análise de dados físico-químicos e microbiológicos das águas de afluente e efluente da ETE (DBO, DQO, SST, STT, N-NH4+, P-PO43-, Óleo e Gordura, SAAM e coliformes fecais, principalmente), e analisada a variação em concentração de contaminantes no rio Torres prévia e posteriormente à construção da ETAR, que realiza um tratamento primário nas águas, tudo associado à estacionalidade. Os dados foram analisados em R versão 3.6.1. De acordo com a metodologia do índice holandês, o rio Torres foi classificado como severamente contaminado prévio à construção da ETAR e, atualmente, aumenta seu grau de contaminação depois da descarga da ETAR, principalmente nas épocas chuvosas. A ETAR apresenta remoção significativa de sete dos oito parâmetros analisados, as porcentagens de remoção mais representativas são: SST (68,5 %), DBO (49,8 %) e Óleo e Gordura (54,7 %). Ficou comprovada a contribuição quantitativa da ETAR para o rio Torres, removendo toneladas de contaminantes das águas residuais de 2015 a 2020, principalmente DQO (26,791.8 Mg), SST (24,162.6 Mg), DBO (12,290.0 Mg) e STT (30,267.7 Mg). Finalmente, ficou clara a necessidade de construir as próximas etapas da ETAR que incluem o tratamento secundário, que melhoraria a remoção de matéria orgânica, surfactantes e nutrientes.engAcceso abiertoAtribución 4.0 Internacionalhttp://creativecommons.org/licenses/by/4.0/REUTILIZACION DEL AGUATRATAMIENTO DE RESIDUOSGESTION AMBIENTALPOLLUTANT LOADSANITATIONAporte ambiental de la planta de tratamiento de aguas residuales Los Tajos en la remoción de contaminantes fisicoquímicos y microbiológicosEnvironmental contribution of Los Tajos wastewater treatment plant in the removal of physicochemical and microbiological pollutantsContribuição ambiental da estação de tratamento de esgoto Los Tajos na remoção de contaminantes físico-químicos e microbiológicoshttp://purl.org/coar/resource_type/c_6501https://doi.org/10.15359/ru.36-1.33